16 May 2012

•       Vortex flowmeter tested at the pigsar test facility under practical conditions.

•       The accuracy of natural gas measurement was better than device specifications at the tested pressures.

•       Advantages for the user: Highly accurate monitoring of natural gas pipelines in the plant, improved burner control and more accurate billing.

Today, natural gas is one of the most important energy carriers in many factory processes with constantly increasing sales. In many companies and plants it is an easy to handle fuel, without which operation is virtually unimaginable. Although the current price tag of around 40 cents per cubic metre seems very low in and of itself, there are considerable costs that come to bear in practice: For example, at this gas price in a DN 100 natural gas pipe at 25 bars of pressure, 35 million euros flow through the pipe per year. In this case, it is worth investing in precise measuring equipment, especially if internal balancing of energy consumption is a goal.

In this application, a vortex flowmeter such as the OPTISWIRL 4070 C provides high accuracy at minimal investment cost. In order to check the characteristics of the OPTISWIRL when measuring natural gas, KROHNE had a production model tested under practical conditions at the pigsar testing facility in Dorsten.

The high pressure gas meter testing facility operated by EON Ruhrgas is the national standard for the Federal Republic of Germany and as such is responsible for maintaining the reference value for unit of volume for high pressure natural gas and passing on this reference value to other laboratories. In association with and under the control of the Federal Institute of Physics and Metrology (PTB), pigsar conducts calibrations and verifications as an independent laboratory.

An OPTISWIRL 4070 C DN150 PN40 featuring integrated pressure and temperature compensation was used as a test device. The purpose of the test was the volumetric measurement (standard cubic metres) of natural gas routed directly to the calibration rig from the EON Ruhrgas operating network. Results were then compared to those of the turbine-type meters used as reference devices. Two series of tests at 16 and 41 bars of pressure were run as these are representative of the prevailing pressure range of 16-40 bar in practice. The result did not only confirm the specific measuring accuracy - it exceeded it considerably: at 16 bar of pressure, the measuring accuracy of the OPTISWIRL only deviates an average of ±0.24% from the turbine, while measuring uncertainty is at ±0.15%. At the higher pressure, the values were even somewhat better with the same measuring uncertainty, measuring inaccuracy was only ±0.135%. This puts the device clearly above the standard specified accuracy of 1% for gases in both tests.

For the user, improved measuring accuracy means more precise monitoring and, in the case of internal balancing that means more accurate billing: In the first example cited, 0.1% measuring accuracy corresponds to a sum of 35000 EUR. The price of an OPTISWIRL (size DN150) does not even amount to a fifth of this.

For further information, please contact:

KROHNE Ltd
34-38 Rutherford Drive
Park Farm Industrial Estate
WELLINGBOROUGH
Northants
NN8 6AE
UK

Tel: +44 (0) 1933 408518
Fax: +44 (0) 1933 408589
Internet: www.krohne.com
PandCT.com are not responsible for the content of submitted or externally produced articles and images.
Click here to email PandCT about any errors or omissions contained within this article.
     
Send this page
To send this page to a colleague or friend,
fill in the email addresses below...
Your email address
Their email address:
Page to be sent: shownews.asp?ID=32925

Company gateway pages
for KROHNE Ltd:
FREE Information on the products in this article
To request more information from this supplier,
fill in your email address below.
Your email address
 
     
Bookmark and Share
Product categories: Accelerometers | Actuators | Agitators | Analysers | Bearings | Compressors | Controllers | Conveyors | Drives | Enclosures | Flowmeters | Heat Exchangers | Motors | Pumps | Relays | Sensors | Transducers | Transmitters | Valves | Weighing
(c) Copyright 1999-2013 Process and Control Today Ltd  |  Reg. no 3733110  |  Email Editor  |  Email Webmaster  |  Sitemap  |  Privacy Policy