Measuring low pulsating flows in large pipes.
16/07/2014 Titan Enterprises Ltd
Commonly low flow liquid movements are generated by a reciprocating motive action peristaltic, piston or diaphragm pump. Using such pumps can cause very large pulsations in liquid pipelines resulting in measurement problems with most inferential flow meters. Likewise turbine flow meters, differential pressure devices and velocity measuring flow meters are also likely to experience problems. Though positive displacement and Coriolis meters will normally handle pulse variations even these flow devices can have problems.The best solution for any flow meter is to remove the pulsations. This is best done in two stages. First regulate the pressure and then install a tuned pulsation damper. The balance between the two will depend on the frequency and amplitude of the pulsations and the solution is only likely to be effective at a given flow, temperature and pressure condition. In some cases the plumbing in the system can work in the users favour. If the meter is located after a long length of flexible tubing a lot of the pulsations will have been reduced to an acceptable level.
If a dead ended column is added where the amount of air stored can be varied with a release valve - an in-built pulsation damper can be formed. From experience it will require some trial and error to establish the correct volume of air for the line pressure but this can be done. However using flexible lines and air after the flow meter can also cause problems as these can induce reverse flow. Depending on the meter type this will manifest as positive flow adding to the metered volume.
Overall with low flow systems it is often better to have solid pipework after the flow meter and flexible before. Also take care when designing your installation to ensure that there are no spaces for any unwanted vapour to collect before or after the flow meter as this can exacerbate pulsation problems.
For more information, please contact:
Trevor Forster
Titan Enterprises Ltd
Coldharbour Business Park
Sherborne
Dorset
DT9 4JW
Tel: +44 1935 812 790
Fax: +44 1935 812 890
Email: trevor@flowmeters.co.uk
Web: www.flowmeters.co.uk
Share article:
Process and Control Today are not responsible for the content of submitted or externally produced articles and images. Click here to email us about any errors or omissions contained within this article.