Portable hydrogen detector protects safety of welding process
10/12/2012 Quantitech Ltd
A nuclear power station in Washington, USA, recently purchased a portable hydrogen analyser from H2scan for the detection of hydrogen during a cask storage welding process. The analyser is able to provide immediate indication of any hydrogen leak and as such represents a vital component of the plant's safety strategy.The analyser, a HY-ALERTA™ 500 is highly sensitive to hydrogen and provides an almost instantaneous warning of any hydrogen leak with a unique visual LED array on the sensor probe. Readings are taken every 10 minutes for the duration of the lid to shell welding process, which typically takes 14 hours.
As a result of a recent procedural change, nuclear facilities are required to purge with an inert gas during welding operations and argon is used during the cask welding process. Importantly, the HY-ALERTA™ 500 is unaffected by argon; it does not require oxygen to operate and is able to function correctly in a wide variety of environmental conditions.
With two sensing elements on the same semiconductor die, the HY-ALERTA™ 500 can detect hydrogen leaks as low as 15 ppm and will not saturate or be destroyed when detecting high concentrations of hydrogen up to 100%. The solid-state sensor does not incorporate any consumables or moving parts and provides a 10 year expected lifespan.
Explaining the advantages of being able to monitor for hydrogen without oxygen, the power station supervisor of reactor maintenance, said "H2scan's HY-ALERTA™ 500 was very reliable, easy to use, and improved our cask welding process. Without this instrument it would not be possible to detect a hydrogen build up during the cask welding process. A flash or burn-through is not only dangerous; it would cause a stoppage of the entire facility.
"Implementing H2scan's analyser allowed operators to closely monitor the hydrogen concentration in real-time and halt the welding process if hydrogen was present."
The HY-ALERTA™ 500 is available in the UK from Quantitech and a video showing the HY-ALERTA™ 500 in operation can be viewed on the Quantitech website www.quantitech.co.uk
For further information, please contact:
Quantitech Ltd
Unit 3
Old Wolverton Road
Milton Keynes
MK12 5NP
t. 01908 227722
f. 01908 227733
Email sales@quantitech.co.uk
Process and Control Today are not responsible for the content of submitted or externally produced articles and images. Click here to email us about any errors or omissions contained within this article.